While the Truck and Large Equipment Cross Draft paint booth design is the simplest airflow design in the market today, it continues to be one of the most popular models. It provides an efficient and affordable solution for coating large equipment, RV’s or whatever you may be painting. The clean air enters through the doors located in the front of the booths and flows through the booth to the exhaust filter bank located in the rear of the cabin. The exhaust filters capture the overspray before exhausting the air from the building. Our standard cross draft truck and large equipment booths are built with 10 Gauge Structure.
Scope:
Clean air flows in through the filtered entry doors located at the front of the booth, moves through the work area, and exits through the exhaust plenum(s) located on the rear wall of the booth. Filtered exhaust air is drawn thru the exhaust plenum and discharged upward into the atmosphere through the exhaust stack(s). This booth is provided complete, with all necessary hardware to meet the applicable national requirements established by OSHA, and the NFPA for paint booth construction.
Our Heavy Duty and Xtreme Duty truck and large equipment paint booths are built with W8X10 I-beam construction. We now offer a standard duty design. This helps reduce the cost but maintains superior construction and quality.These booths are offered in many standard sizes but can also be customized to meet your needs. Also, available in pressurized, non-pressurized, reverse flow, solid back and drive thru models.
We also have double wall insulated Truck and Large Equipment booths available in all models. These booths are constructed with HD I beams and two layers of 20-gauge pre-coated sheet metal.
Booths are constructed from 18-gauge, quality galvanized steel. All supports and panels are CNC punched for easy nut and bolt assembly. Beams are fabricated from formed 10 Gauge Galvanized Steel. Support is pre-punched to match corresponding panels. Support is placed on maximum 10' centers for added rigidity. Columns are fabricated from formed 10 Gauge Galvanized Steel. Support is pre-punched to match corresponding panels. Support is placed on maximum 10' centers for added rigidity. Optional I Beam Construction is available.
Product doors are field hung on slotted hinges to aid in adjustment on two axis for uneven floors. Our standard 36″ wide personnel door has an observation window and is set into pre-assembled heavy duty frame.
Beams are fabricated from formed 10 Gauge Galvanized Steel. Support is pre-punched to match corresponding panels. Support is placed on maximum 10' centers for added rigidity. Columns are fabricated from formed 10 Gauge Galvanized Steel. Support is pre-punched to match corresponding panels. Support is placed on maximum 10' centers for added rigidity.
Product doors are field hung on slotted hinges to aid in adjustment on two axis for uneven floors. Our standard 36″ wide personnel door has an observation window and is set into pre-assembled heavy duty frame.
Fixtures are Maintenance-Free rated for Class I Division II Groups A, B, C, D; Class II Division II Groups F & G. Fixtures are ETL listed and approved for their intended use and placement. Lighting is provided by innovative LED technologies consisting of multiple high efficiency flux boards paired with high efficiency drivers. Fixtures are designed to accept either 120VAC or 277VAC power. Drivers and boards carry a 5-year limited warranty.
Clean air flows in through the filtered entry doors located at the front of the booth, moves through the work area, and exits through the exhaust plenums located on the rear wall of the booth. Filtered exhaust air is drawn thru the exhaust plenum and discharged upward into the atmosphere through the exhaust stacks. This booth is provided complete, with all necessary hardware to meet the applicable national requirements established by OSHA, and the NFPA for paint booth construction.
The sizes listed below are standard catalog sizes. We can custom build all of our finishing equipment to meet your needs. Call us at 800-637-4027.
Interior Dimensions | Exterior Dimensions | Access Doors | Nominal Door Openings | Illumination | Fan Spec | ||||||||
Width | Height | Length | Width | Height | Length | Width | Height | Qty | Type | Total | Dia. | HP | |
16′ | 16′ | 34′ | 17′ | 16’6″ | 34’4″ | 1 | 11’4″ | 13’10.5″ | 1 | Filtered | 24 | 42″ | 7.5 Hp |
16′ | 16′ | 34′ | 17′ | 16’6″ | 34’4″ | 1 | 11’4″ | 13’10.5″ | 1 | Solid | 24 | 42″ | 7.5 Hp |
16′ | 16′ | 34′ | 17′ | 16’6″ | 34’4″ | 1 | 11’4″ | 13’10.5″ | 2 | 1 Each | 24 | 42″ | 7.5 Hp |
16′ | 16′ | 44′ | 17′ | 16’6″ | 44’4″ | 2 | 11’4″ | 13’10.5″ | 1 | Filtered | 32 | 42″ | 7.5 Hp |
16′ | 16′ | 44′ | 17′ | 16’6″ | 44’4″ | 2 | 11’4″ | 13’10.5″ | 1 | Solid | 32 | 42″ | 7.5 Hp |
16′ | 16′ | 44′ | 17′ | 16’6″ | 44’4″ | 2 | 11’4″ | 13’10.5″ | 2 | 1 Each | 32 | 42″ | 7.5 Hp |
16′ | 16′ | 54′ | 17′ | 16’6″ | 54’4″ | 3 | 11’4″ | 13’10.5″ | 1 | Filtered | 40 | 42″ | 7.5 Hp |
16′ | 16′ | 54′ | 17′ | 16’6″ | 54’4″ | 3 | 11’4″ | 13’10.5″ | 1 | Solid | 40 | 42″ | 7.5 Hp |
16′ | 16′ | 54′ | 17′ | 16’6″ | 54’4″ | 3 | 11’4″ | 13’10.5″ | 2 | 1 Each | 40 | 42″ | 7.5 Hp |
16′ | 16′ | 64′ | 17′ | 16’6″ | 64’4″ | 4 | 11’4″ | 13’10.5″ | 1 | Filtered | 48 | 42″ | 7.5 Hp |
16′ | 16′ | 64′ | 17′ | 16’6″ | 64’4″ | 4 | 11’4″ | 13’10.5″ | 1 | Solid | 48 | 42″ | 7.5 Hp |
16′ | 16′ | 64′ | 17′ | 16’6″ | 64’4″ | 4 | 11’4″ | 13’10.5″ | 2 | 1 Each | 48 | 42″ | 7.5 Hp |
Also Available in 18′ and 20′ Wide Models Call for Pricing 1-800-637-4027 | |||||||||||||
This booth intakes fresh air from the filtered front doors it. The air is pulled across the parts being painted to the exhaust filter bank located at the rear of the booth. The air is then filtered and exhausted in through the duct work.
All Our Booths NOW Have LED Lighting!
Fixtures are Maintenance-Free rated for Class I Division II Groups A, B, C, D; Class II Division II Groups F & G. Fixtures are ETL listed and approved for their intended use and placement. Lighting is provided by innovative LED technologies consisting of multiple high efficiency flux boards paired with high efficiency drivers. Fixtures are designed to accept either 120VAC or 277VAC power. Drivers and boards carry a 5-year limited warranty. To find out more about LED light fixtures, please click here.
Our factory trained installation crew can get your new Truck and Large Equipment Cross Draft Paint Booth installed correctly and quickly.
This our specialty! You can rest assured that your new equipment will be operational in no time.